CASE STUDY: APPLYING THE COSMIC ISO 19761 MEASUREMENT METHOD ON AN MRI MESH GENERATION MEDICAL APPLICATION

AbuTalib, F., Giannacopoulos, D., Abran, A.

This paper addresses the problem of applying the COSMIC ISO
19761 measurement method on a Magnetic Resonance Imaging
(MRI) medical software application. The application in our
case study uses 3D constrained Delaunay triangulated
algorithms to generate volumetric meshes from the segmented
2D MRI images. The various steps of the measurement method
are explored and discussed in details after analyzing the
requirements and the system architecture of the application.
Examples are presented to illustrate how the measurement
results obtained can be beneficial to researchers evaluating and
comparing such applications.

Publishing date
01-06-2012
Conference
ISSPA
Download option
Allow direct download